Inverter EH9335-80KS off grid of big volotage and power
Application field
The EH9335 series is the best choice for data centers, network management centers, and enterprise server rooms in various industries or fields such as telecommunications, finance, transportation, government, manufacturing, and energy.
Product performance
•Three in three out / three in single out UPS
The series is a three-in and three-out UPS. The input current is three-phase balanced, which can equalize the load of the three-phase power grid; the output can be changed to single-phase output.
•Digital control
All parts of the UPS are digitally controlled. The UPS has excellent performance indicators, high system stability, self-protection and fault diagnosis capabilities, and avoids the risk of analog device failure, making the control system
more stable and reliable.
•The number of external batteries is optional (±16/18/20 sections are optional)
The number of external batteries for this series of UPS can be selected according to the user’s needs: ±16/18/20 knots.
•Charging current can be set
This series of UPS automatically assigns a reasonable charge current by setting the user-configured battery capacity.
Constant voltage charging mode, constant current charging mode and floating charging mode can automatically and
smoothly switch.
•Intelligent monitoring function
This series of UPS can realize remote monitoring of UPS when an optional SNMP card is selected.
•Smart charging method
This series of UPS uses an advanced two-stage three-stage charging method.?The first stage is high constant current charging, quickly recharge about 90% of the power; the second stage of constant voltage charging, can activate the battery characteristics and fully charge the battery; the third stage is floating charge mode.This can balance the goal of fast charging and extending battery life, saving users’ battery investment.
•LCD display
This series of UPS uses LCD and LED dual display, which allows users to more intuitively understand the working status and operating parameters of the UPS such as input/output voltage and frequency load capacity, battery capacity and internal temperature, so that all operations can be seen at a glance
•EPO Function
An emergency shutdown (EPO) button is embedded on the UPS unit panel,user can externally connect the EPO button.
Press the EPO button in an emergency to shut down urgently; and have a remote emergency shutdown (REPO) function.
TECH SPECS
Model | EH9335 PRO -20KS |
EH9335 PRO -30KS |
EH9335 PRO -40KS |
EH9335 PRO -60KS |
EH9335 PRO -80KS |
||
Power | 20KVA/18KW | 30KVA/27KW | 40KVA/32KW | 60KVA/54KW | 80KVA/64KW | ||
Input | Input | Three-phase four-line + ground | |||||
Rated Power | 380/400/415Vac | ||||||
Voltage Range | 208~478Vac | ||||||
Frequency Range | 45-55Hz at 50Hz/54-66Hz at 60Hz(Auto sensing) | ||||||
Power Factor | ≥ 0.99 | ||||||
Input Current Harmonic | ≤ 3%(100%Nonlinear load ) | ||||||
Bypass Range | Bypass protection voltage upper limit:220V: + 25%(Optional+ 10%,+ 15%,+ 20%); 230V:+ 20%(Optional+ 10%,+15%); 240V:+ 15% (Optional+10%) |
||||||
Bypass protection voltage lower limit:-45%(Optional -20%,-30%) | |||||||
Bypass frequency protection range:±10% | |||||||
Output | Output | Three-phase four-line + ground or single phase+N | |||||
Rated Voltage | 380/400/415Vac or 220/230/240Vac | ||||||
Voltage accuracy | ±1% | ||||||
Output Frequency | Utility Mode | Synchronous with input; when the mains frequency exceeds ±10% maximum (±1%, ±2%, ±4%,±5% can be set), the output frequency is 50*(±0.2)Hz |
|||||
Battery Mode | (50/60±0.2%)Hz | ||||||
Load peak Ratio | 3:1 | ||||||
Output Voltage Disortion | ≤ 2% Linear Load ≤ 5% Nonlinear Load |
||||||
Battery | Efficiency | Normal Mode≥ 94.5% | |||||
Battery Voltage | Optional :±192V±216V±240V DC (±16/18/20 P CS) | ||||||
Charging Current | 10A max | ||||||
Transfer time | Utility mode to bypass mode: 0ms (tracking); utility mode to battery mode: 0ms | ||||||
Protection | Overload Capability | Normal Mode | Load ≤ 110%, 10mins, ≤ 125%, maintain 1mins, ≥ 150% shut down immediately. |
||||
Over Temperature Protection | Normal mode: switch to bypass mode; Batter mode: Turn off the output immediately. | ||||||
Emergency shutdown (EPO) |
Turn off the output immediately | ||||||
Operating Environment | Communication Connection | USB, RS485, dry contact, parallel (optional), SNMP card (optional), relay card (optional) | |||||
Working Temperature | 0o C ~ 40o C | ||||||
Storage Temperature | -25o C ~ 55o C | ||||||
Relative Humidity | 0℃~55℃ NO condensation | ||||||
Altitude | < 1500m, when above 1500m, derate according to GB/T 3859.2 | ||||||
Physical characteristics | Size (D*W*H) | 724*250*734mm | 805*335*978mm | ||||
Net Weight(kg) | 45 | 46 | 48 | 80.5 | 82.5 | ||
Executive standard | YD/T1095-2008 |